HLA Phenotyping (Scheme 1A)
ACCREDITATION STATUS:
UKAS Schedule of Accreditation, Accredited to ISO/IEC 17043:2010 Provider 8351
CLINICAL APPLICATION:
HLA Typing
PURPOSE OF PROGRAMME:
To assess participants' ability to use serological and supplementary methods to correctly identify HLA specificities
ANALYTES:
Analyte | Default Unit |
---|---|
HLA-A | HLA-A, B, C, DR, DQ typing or any combination of these using serological techniques |
HLA-B | HLA-A, B, C, DR, DQ typing or any combination of these using serological techniques |
HLA-C | HLA-A, B, C, DR, DQ typing or any combination of these using serological techniques |
HLA-DQ | HLA-A, B, C, DR, DQ typing or any combination of these using serological techniques |
HLA-DR | HLA-A, B, C, DR, DQ typing or any combination of these using serological techniques |
MATERIAL PROVIDED: Blood OR isolated lymphocyte preparations (non-UK participants only)
DISTRIBUTIONS PER YEAR: 5
SAMPLES PER DISTRIBUTION: 2
FREQUENCY OF DISTRIBUTION: As per Distribution Timetable
PROGRAMME OF ANALYSIS:
Results should be submitted via online data entry. Results are expected to be returned within the specified reporting period (please refer to results deadline for each distribution on the UK NEQAS for H&I website or Participants Manual). The majority of UK NEQAS for H&I schemes are assessed on a consensus basis, therefore samples are distributed with the assigned value not being determined. Where a reference result is used, this testing is performed alongside or after the close of the EQA scheme. For these reasons UK NEQAS for H&I is unable to disclose results early.
DATA ANALYSIS:
Qualitative analysis.
PERFORMANCE SCORING:
Participants will be assessed on the HLA loci for which they are registered. The consensus complete HLA phenotype for assessment is determined by at least 75% of laboratories agreeing each specificity. Specificities failing to reach the 75% consensus level will not be assessed.
PERFORMANCE MONITORING:
Satisfactory Performance is obtaining nine or more complete HLA phenotypes in agreement with the consensus phenotypes in a year.
PERSISTENT POOR PERFORMANCE:
Laboratories not meeting the Satisfactory Performance criteria are deemed to have Unsatisfactory Performance and must complete a root cause, corrective and preventative action form.
Histocompatibility & Immunogenetics
The External Quality Assessment Scheme for Histocompatibility and Immunogenetics was founded in 1975 by Dr Heather Dicks and Dr Colin Entwistle at the National Tissue Typing and Reference Laboratory (NTTRL) based at Southmead Hospital in Bristol. In 1989 the Service became known as the UK National External Quality Assessment Service for Histocompatibility and Immunogenetics with Dr Peter Klouda as the service director and Mr Terry Ray as the service manager. The service relocated to a new host organisation in September 2000. UK NEQAS for Histocompatibility and Immunogenetics is now part of the Welsh Blood Service. For the most up-to-date scheme information (including any pilot schemes) please contact the centre directly.